西门子代理商SITOP PSU100S 24 V/5 A 稳定电源 6EP1333-2BA20-宣传视频
6EP1333-2BA20SITOP PSU100S 24 V/5 A 稳定电源 输入:120/230 V AC 输出:24 V/5 A DC *EX 批准不 可用*0" box-sizing: border-box;padding: 0.5rem 0.2rem;display: block">附件类似产品 0" https://mall.industry.siemens.com/mall/collaterals/files/151/jpg/P_KT01_XX_01341t.jpg"/>6EP1961-2BA31SITOP PSE200U 3 A 选择性模块 4 通道 输入:24 V DC/12 A 输出:24 V DC/4x 3 A 可调阈值 0.5-3 A 每个输出端带一个状态消息 *EX 批准不 可用*6EP1961-2BA51SITOP PSE200U 3 A NEC 等级 2 选择性模块 4 通道 输入:24 V DC/12 A 输出:24 V/4x 3A NEC 等级 2 可调阈值 0.5-3 A 带总信号触点 *EX 批准不 可用*6EP1964-2BA00SITOP PSE202U 10A 冗余模块 输入端/输出端:24 V DC 适合用来将两个各带有 最多 20A 输出电流 最多各 5 A 输出电流6EP4438-7FB00-3DX0SITOP SEL1200 选择性模块 8 通道 切换特性 输入:24 V DC/60 A 输出:24 V DC/8 x 10 A 可调阈值 2-10 A 带监控接口 *EX 批准不产品商品编号(市售编号)6EP1333-2BA20产品说明SITOP PSU100S 24 V/5 A 稳定电源 输入:120/230 V AC 输出:24 V/5 A DC *EX 批准不 可用*产品家族单相, 24 V DC产品生命周期 (PLM)PM300:有效产品价格数据价格组 / 总部价格组DA / 582列表价(不含税)显示价格您的单价(不含税)显示价格金属系数无交付信息出口管制规定AL : N / ECCN : N工厂生产时间1 天净重 (Kg)0.400 Kg包装尺寸14.00 x 13.00 x 6.00包装尺寸单位的测量CM数量单位1 件包装数量1其他产品信息EAN4025515153481UPC未提供商品代码85044083LKZ_FDB/ CatalogIDKT10-PE产品组4207组代码R315原产地奥地利Compliance with the substance restrictions according to RoHS directiveRoHS 合规开始日期: 2006.08.01产品类别A: 问题无关,即刻重复使用电气和电子设备使用后的收回义务类别-REACH Art. 33 责任信息Lead CAS 号 7439-92-1 > 0, 1 % (w / w)分类版本分类eClass1227-04-07-01eClass627-04-90-02eClass7.127-04-90-02eClass827-04-90-02eClass927-04-07-01eClass9.127-04-07-01ETIM7EC002540ETIM8EC002540ETIM9EC002540IDEA44130UNSPSC1539-12-10-04西门子PLC系统块数据保持设置数据保持设置定义CPU如何处理各数据区的数据保持任务。在数据保持设置区中选中的就是要“保持”其数据内容的数据区。所谓“保持”就是在CPU断电后再上电,数据区域的内容是否保持断电前的状态。1.保持:选中的数据区内容会保持断电前状态2.不保持:如果某数据区未设置为“保持”,则在CPU重新上电时,V存储区的内容会用EEPROM的内容覆盖(通常都是0),如果EEPROM中保存了数据(如在数据块中设置了V数据区的初始值),这些数据就会自动复制到V区中;其他数据区的内容会清零在这里设置的数据保持功能靠如下几种方式实现:1.CPU内置的超级电容2.超级电容放电完毕后,如果安装了外插电池(或CPU221/222用的时钟/电池)卡,则电池卡会继续数据保持的电源供电,直到放电完毕3.数据在断电前被自动写入相应的EEPROM数据区中(如果设置MB0 - MB13为保持)图1. 设置数据保持范围在上图中:a.最多可以设置6个数据保持区域b.选择数据保持区的存储区类型(V、M、T和C的当前值)c.指定数据保持区的起始地址:相对于地址0的偏移值,如14就是起始地址为MB14d.存储单元的个数(在b.中指定的数据单元的个数)e.清除当前的设置(为不保持)如果将MB0 - MB13共14个字节范围中的存储单元设置为“保持”,则CPU在断电时会自动将其内容写入到EEPROM的相应区域中,在重新上电后用EEPROM的内容覆盖这些存储区。也就是能做到yongjiu保存。如上图蓝圈内所示。数据区设置为不保持时,可以将CPU断电然后再上电、在Status Chart(状态表)中检查相应地址单元内容是否改变可以检验数据是否正确地存入EEPROM。以上的“保持”设置(除了MB0 - MB13)都是靠内置超级电容( 外插电池卡)的方式供电实现。定时器T和计数器C的当前值可以保持,而它们的位地址状态不能保持。只有TONR定时器数据才能保持。3RW55 软起动器SIRIUS 3RW55 软起动器装置系列SIRIUS 3RW55 高性能型软起动器具有十分完备的功能,能够可靠完成困难的起动和停止操作。由于采用创新的转矩控制,该装置可用于输出功率在 5.5 kW 和 1200 kW(400 V 下)之间的驱动装置。这些功能经过专门设计,具有很高的用户友好性。借助于可拆卸的 HMI(带彩色显示屏、本地接口和 Micro SD 存储卡插槽)和插入式通信模块(PROFINET、PROFIBUS、Ethernet IP 和 Modbus),应用十分灵活。由于采用现代混合分断技术,SIRIUS 3RW55 软起动器可执行高效分断,实现长期节能应用。SIRIUS 3RW55 高性能型软起动器及附件优势SIRIUS 3RW55 Keyvisual 软起动器产品特性/功能性能/优点自动参数设置调试极为方便,甚至在变化的负载条件下也具有高可靠性混合开关技术与三相电机控制极低功耗以及最优/对称电机控制TIA 集成 – 可选配通信模块在自动化工程中实现高效组态和灵活应用可拆卸 HMI 带有彩色显示屏、本地接口和微型 SD 卡插槽灵活的用户界面和直观的菜单引导操作泵停止功能和转矩控制功能低机械载荷和最优停泵控制根据 ATEX/IECEx 指令进行了认证适合起动防爆型电机系统冗余 S2可以简便、直观地集成到容错自动化系统中通过 OPC UA 服务器直接集成到 MindSphere全球数据可用性,优化工厂运行组态More informationTechnical specifications, see https://support.industry.siemens.com/cs/ww/en/ps/25099/tdFAQs, see https://support.industry.siemens.com/cs/ww/en/ps/25099/faqEquipment Manual, see https://support.industry.siemens.com/cs/ww/en/view/109753752Simulation Tool for Soft Starters (STS), see https://support.industry.siemens.com/cs/ww/en/view/101494917Type 3RW55133RW55143RW55153RW55163RW5517Rated operational current IeA1318253238Power electronicsLoad rating rated operational current IeIEC + UL/CSA individual mounting at 40/50/60 °C, AC?53aA13/11.5/10.518/15.9/13.825/22.3/19.632/28.4/2638/33.5/30.5Permissible rated motor current and starts/hNormal starting (CLASS 10A)Rated motor current IM; Tu = 40/50/60 °CON period = 70%; motor protection activatedA13/11.5/10.518/15.9/13.825/22.3/19.632/28.4/2638/33.5/30.5300% IMStartup time 5 s1/h4343434343Startup time 10 s1/h1818181818350% IMStartup time 5 s1/h2828282828Startup time 10 s1/h1010101010Normal starting (CLASS 10E)A13/11.5/10.518/15.9/13.825/22.3/19.632/28.4/2638/33.5/30.5300% IMStartup time 10 s1/h2121212121Startup time 20 s1/h88888350% IMStartup time 10 s1/h1313131313Startup time 20 s1/h44444Heavy starting (CLASS 20E)A13/11.5/10.518/15.9/13.825/22.3/19.629.6/27.2/23.633.5/30.5/27.5300% IMStartup time 20 s1/h1010101010Startup time 40 s1/h44444350% IMStartup time 20 s1/h77777Startup time 40 s1/h2.52.52.52.52.5Heavy starting (CLASS 30E)A13/11.5/10.518/15.9/13.825/22.3/19.626/23.6/21.229/26/23300% IMStartup time 30 s1/h77777Startup time 60 s1/h33333350% IMStartup time 30 s1/h44444Startup time 60 s1/h1.81.81.81.81.8Adjustable rated motor current IMMinimum/maximumA2.5/133.5/185/256.5/327.5/38Minimum/maximum in inside-delta circuitsA4.3/22.56.1/31.18.7/43.311.3/55.413/65.8Type 3RW55213RW55243RW55253RW55263RW5527Rated operational current IeA2547637793Power electronicsLoad rating rated operational current IeA25/22.3/19.647/41.6/36.263/55.5/50.577/68/6293/82.5/75.5Permissible rated motor current and starts/hNormal starting (CLASS 10A)A25/22.3/19.647/41.6/36.263/55.5/50.577/68/6293/82.5/75.5300% IMStartup time 5 s1/h4343434343Startup time 10 s1/h1818181818350% IMStartup time 5 s1/h2828282828Startup time 10 s1/h1010101010Normal starting (CLASS 10E)A25/22.3/19.647/41.6/36.263/55.5/50.577/68/6293/82.5/75.5300% IMStartup time 10 s1/h2121212121Startup time 20 s1/h88888350% IMStartup time 10 s1/h1313131313Startup time 20 s1/h44444Heavy starting (CLASS 20E)A25/22.3/19.647/41.6/36.263/55.5/50.577/68/6293/82.5/75.5300% IMStartup time 20 s1/h1010101010Startup time 40 s1/h44444350% IMStartup time 20 s1/h77777Startup time 40 s1/h2.52.52.52.52.5Heavy starting (CLASS 30E)A25/22.3/19.643.4/38/34.453/48/4368/62/5682.5/75.5/65300% IMStartup time 30 s1/h77777Startup time 60 s1/h33333350% IMStartup time 30 s1/h44444Startup time 60 s1/h1.81.81.81.81.8Adjustable rated motor current IMMinimum/maximumA5/2510/4713/6316/7719/93Minimum/maximum in inside-delta circuitsA8.7/43.317.3/81.422.5/10927.7/13332.9/161